회사소개   사업소개   연구개발   인재채용   홍보센터
 
 
ALS Specification > Business Division > Renewable Energy > Test & Simulation > ALS Specification
 
ACTIVE LOAD/SOURCETM
Compared to other electronic power load which consumes the whole energy, Active Load/Source restores the electronic energy mostly for power saving and testing the big capacity.
 
 
Features

Applied for both DC & AC(single phase/three phase three wire/ three phase four wire)

Display various wave and enter the parameters

Remote Control & monitoring

Transient Response Time (Step/Ramp Change
Selecting mode between LOAD and SOURCE.
[ LOAD Mode ]
- Programmable load current (linear, capacitive, non-linear, etc)
- Enter specific harmonic distortion
[ SOURCE Mode ]
- Programmable output current(sinusoidal wave, trapezoidal wave, etc)
- Operating mode selection in constant voltage/constant current/constant power
 
Specification

Capacity: (Standard) 10kW~1MW, (On demand)1MW~10MW

Frequency Range (Standard) 1~120Hz, (On demand) 1~1KHz

Accuracy : Less ± ¾1%

Current Accuracy : Less ± ¾1%

Ripple Noise : Less ±¾0.5%